The MWM gas engines of the TCG 2020 series are perfectly geared to the challenges of a dynamic market environment. With outputs ranging from 1,000kWe – 2,000kWe, the TCG 2020 meets the high requirements of a broad range of applications and guarantee efficiency, reliability, flexibility, and environmental sustainability, together with low lifecycle costs and high profitability.
The TCG 2020 is highly efficient thanks to its optimised inlet duct, combustion chamber and spark plugs. You can save as much as 15% per annum on fuel costs – and increase your plant’s profitability.
With its optimised engine components, the TCG 2020 requires up to 50% less lubricating oil than other similar gensets. In terms of efficiency that means long-term savings.
Whether you need high efficiency or an optimised standalone unit with good load compensation and black start properties, we can provide you with an engine that is tailored exactly to your needs.
TEM (Total Electronic Management) controls not just the engine… but the entire system including the heat supply from cogeneration. Temperature monitoring for each cylinder and anti-knock control ensure the best possible utilisation of fuel and maximum power output, even if gas composition fluctuates.
The gas-mixer and TEM allows use for a wide variety of gases. Even the most problematic gases such as landfill gas and sewage gas can be used without difficulty.
TCG 2020 | V12 (1.0)[2] | V12 K (1) | V12 K (1) | V12 (2) | V16 K | V16 (2) | V20 (2) | V20 (HE) [2] |
Engine type | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz |
Electrical output | 1,000kW | 1,000kW | 1,125kW | 1,200kW | 1,500kW | 1,560kW | 2,000kW | 2,000kW |
Mean effective pressure | 15.5 bar | 15.5 bar | 17.4 bar | 18.6 bar | 17.5 bar | 18.1 bar | 18.6 bar | 18.6 bar |
Thermal output ± 8% | 1,057kW | 1,177kW | 1,253kW | 1,190kW | 1,675kW | 1,580kW | 1,977kW | 1,912kW |
Electrical efficiency | 43.0% | 40.0% | 40.9% | 43.6% | 40.9% | 43.2% | 43.7% | 44.4% |
Thermal efficiency | 45.4% | 47.0% | 45.6% | 43.3% | 45.7% | 43.8% | 43.2% | 42.5% |
Overall efficiency | 88.4% | 87.0% | 86.5% | 86.9% | 86.6% | 87.0% | 86.9% | 86.9% |
Power to heat ratio ** | 0.95 | 0.84 | 0.90 | 1.00 | 0.89 | 0.99 | 1.01 | 1.01 |
TCG 2020 | V12 (1.0)[2] | V12 (2) | V16 (2) | V20 (2) |
Engine type | 50 Hz | 50 Hz | 50 Hz | 50 Hz |
Electrical output | 1,000kW | 1,200kW | 1,560kW | 2,000kW |
Mean effective pressure | 15.5 bar | 18.6 bar | 18.1 bar | 18.6 bar |
Thermal output ± 8% | 1,037kW | 1,194kW | 1,577kW | 2,012kW |
Electrical efficiency | 42.6% | 43.0% | 42.6% | 43.0% |
Thermal efficiency | 44.2% | 42.8% | 43.1% | 43.3% |
Overall efficiency | 86.8% | 85.8% | 85.7% | 86.3% |
Power to heat ratio ** | 0.97 | 1.00 | 1.00 | 1.00 |
* With 5% O2 and dry exhaust gas
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
TCG 2020 | V12 (1.0)[2] | V12 K (1) | V12 K (1) | V12 (2) | V16 K | V16 (2) | V20 (2) | V20 (HE) [2] |
Engine type | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz |
Bore / stroke | 170/195mm | 170/195mm | 170/195mm | 170/195mm | 170/195mm | 170/195mm | 170/195mm | 170/195mm |
Displacement | 70.8dm3 | 70.8dm3 | 53.1dm3 | 53.1dm3 | 70.8dm3 | 70.8dm3 | 88.5dm3 | 88.5dm3 |
Speed | 1500min-1 | 1500min-1 | 1500min-1 | 1500min-1 | 1500min-1 | 1500min-1 | 1500min-1 | 1500min-1 |
Mean piston speed | 9.8m/s | 9.8m/s | 9.8m/s | 9.8m/s | 9.8m/s | 9.8m/s | 9.8m/s | 9.8m/s |
Length | 4660mm | 4660mm | 4790mm | 4790mm | 5430mm | 5430mm | 6200mm | 6200mm |
Width | 1810mm | 1810mm | 1810mm | 1810mm | 1810mm | 1810mm | 1710mm | 1710mm |
Height | 2210mm | 2210mm | 2210mm | 2210mm | 2210mm | 2210mm | 2190mm | 2190mm |
Dry weight genset | 11200kg | 11200kg | 11700kg | 11700kg | 13300kg | 13300kg | 17900kg | 17900kg |
TCG 2020 V12, V16, V20, V12K, V12K1, V16 | First service (check valve clearance) * | Cylinder head inspection | General overhaul |
Natural gas | 4000 Oh | 32000 Oh * | 64000 Oh |
Purified biogas, landfill gas, and sewage gas | 4000 Oh | 32000 Oh * | 64000 Oh |
Unpurified biogas, landfill gas, and sewage gas | 2000 Oh | 16000 Oh * | 64000 Oh |
TCG 2020 V12 (1.0) | First service (check valve clearance) * | Cylinder head inspection | General overhaul |
Natural gas | 4000 Oh | 40000 Oh * | 80000 Oh |
Purified biogas, landfill gas, and sewage gas | 4000 Oh | 32000 Oh * | 64000 Oh |
Unpurified biogas, landfill gas, and sewage gas | 2000 Oh | 16000 Oh * | 64000 Oh |
Oh – Operational Hours
* "at the latest"